Currently it only shows your basic business info. Start adding relevant business details such as description, images and products or services to gain your customers attention by using Boost 360 android app / iOS App / web portal.
We also offer Bi Drum oil cum gas fired steam boilers also. This kind of boiler implements the structure of two fold longitudinal drums and D-type furnace. It has a water tube design; the economizer and other supplementary heating surface are preset in the rear. The combustor is situated on the front wall. The convection tube bank and rear heating surface from the reverse of the furnace, and then into the air all the way through the chimney. Body Structure Features: For the twofold drums longitudinal D-type boiler, the stress body has a good condition of stress. Drums and other significant pressure parts won't be emitted and corroded by soaring temperature flame. The Pressure parts, with minute thermal stress, can draw out and draw back easily, and can arrive at higher security border. Auto protect, long-distance control, safety operation OPERATING RANGE: Capacities: ranges from 6 TPH to 40 TPH Pressure: Maximum pressure is of 45.0 Kg per cm2 (g) Temperature: Up to 450ºC Firing fuels: Automatic Oil (Gas) Fired Steam Boiler.
INR 0 INR 0
Availability:True
Pay mode:COD only
IBR Solid Fuel Fired Steam Boilers (IFB) are three pass wet pack, horizontal, smoke tube type fusion welded boiler. They are made to IBR / DIN / BS / ASME code as per requirement of clients. Components are Engineered for maximum safety, Highest Efficiency, dependability and quite operation. Wet back Models eliminate rear end refractory and its inherent maintenance cost, reduces stress of rear tube sheet and ligament cracking, The radiant heat is eliminated lengthening tube life and reducing heat loss. Our integral furnace submerged below water level ensuring complete utilization of heat liberated in the furnace. Apart from the Coal & Lignite the Solid Fuel Fired boiler can also be burnt with Biomass, Briquettes, Groundnut Shells, Coconut Shells, Cashew Shells, Sugarcane and Wood husk to ensure environment friendly flue. Boilers can be supplied with Mechanical dust collector, Water preheater & Air preheater with Rotary Airlock Valve to prevent pollution. Capacity: 500 Kgs/hr - 6000 Kgs/hr. Working Pressure: 10.54 Kg/cm² - 21 Kgs/cm²
INR 0 INR 0
Availability:False
Pay mode:COD only
Steam PRDS is used for Steam Conditioning Services for reduction of pressure and temperature of steam. It is a combination of Control Valve for the pressure reduction purpose & atomizing nozzles, through which water is sprayed into steam for reducing the temperature. Split PRDS: separate PRV (Pressure Reducing Valve) and DeSuperheater Combined PRDS: Both PRV and DeSuperheater in a compact single unit Combined PRDS helps to save the space and also cost of piping, as the unit is single and compact. For PRDS control system, there will be one Pressure loop and one temperature loop. Pressure control system includes pressure sensor, pressure transmitter, controller, I/P Converter, Pressure gauges, etc. Temperature control system includes temperature sensor, transmitter, controller, I/P Converter, Temperature gauges, etc. Spray water quantity required for the temperature reduction of the steam is controlled by separate spray water valve.
INR 0 INR 0
Availability:True
Pay mode:COD only
The horizontal multi pass direct fired FBC hot gas generator is designed with fuel flexibility in mind and can fire a range of use saw dust, rice husk, pulverizes coal, and any type of free flow fuel. It allows high and medium process temperatures without operating pressures. Products Features: High capacity heating system Multi-fuel option Rugged - requires very little maintenance User-friendly systems Operating Range: Capacities from 0.4 million kcal/hr to 15.0 million kcal/hr Temperature: up to 400 ºC Firing fuels: saw dust, rice husk, pulverizes coal, and any type of free flow fuel Efficiency: Overall efficiency of 9o % (+/-2%) on NCV
INR 0 INR 0
Availability:False
Pay mode:COD only
Small Industrial boilers or SIB’s or abbreviated as Small Industrial Boilers are also known as steam generating units. As per the Indian Boiler Regulations, 1950 of Reg. 618-622 Chapter XIV states that:- Any shell type steam generating boiler under the pressure of upto 7 Kg/cm2 and having a volumetric capacity of all pressure parts connected to the same boiler is greater than 25 Litres but less than 500 Litres are known as shell type Small Industrial Boilers.
INR 0 INR 0
Availability:True
Pay mode:COD only
We also provides Annual Maintenance services for Steam boilers and Thermic Fluid heaters. So when you need preventative or emergency service, you must call professionals who not only understand the design & features of your equipment, but also the complex nature of your business. Our goal is to ensure your system’s safety, maximize your efficiency, and minimize your downtime we offers the experience through its engineering support to perform everything from routine maintenance and on-site repair to meeting your upgrade and replacement needs. Keeping your equipment running safely is paramount to your success. When you call our trained service technicians, you’re calling for outstanding service to keep your system in top health.
INR 0 INR 0
Availability:True
Pay mode:COD only
The Company is promoted and backed up by qualified and experienced professional Mr. S.K. Chhabra , a Mechanical engineer by qualified and experience of almost 25 years. So we provide expert level boiler and heater consultancy to your business. This gives us immense strength when we undertake project consultancy in the field of energy conservation and efficiency improvements related to boilers and Thermic Fluid Heaters.
INR 0 INR 0
Availability:False
Pay mode:COD only
We provides preventive and emergency service for your Boiler and Thermic fluid heater. Our goal is to ensure your system’s safety, maximize your efficiency, and minimize your downtime. Backed by more than 10 years of innovation in the industry, We offers the experience through its engineering support to perform everything from routine maintenance and on-site repair to meeting your upgrade and replacement needs to Break down services also.
INR 0 INR 0
Availability:True
Pay mode:COD only
Daily log of steam boiler operation may be helpful. Chart boiler pressure, temperature, CO2, O2, steam or condensate flow, and other data from the boiler. ... Shut off equipment or steam valve, wait a few minutes and then restart. Boiler operation is complicated, especially for modern boilers that are fully automatic. Safety, efficiency, and constant generation of steam or hot water depend on the smooth operation of the boiler. Moreover, some jurisdictions have laws and rules on the boiler operation and boiler operators. On the other hand, maintenance is performed on the boilers to increase efficiency, ensure safety, and prevent unscheduled shutdowns. A maintenance program should be established based on the type of boiler, history, and the age of the boiler.
INR 0 INR 0
Availability:True
Pay mode:COD only